| begin_photen | | # define photon energies of input beam
|
| 641.55 | | # strongly recommended to fit XAS parameters before RIXS calculation |
| 643.55 |
| end_photen |
| scaler_coulomb | 0.8 | # scale first principles matrix elements el-el interaction, for screening
|
| scaler_xtal_field | 1.4 | # scale Xtal field charges to parametrize the ligand field |
scaler_so_coupling |
0.97 | # scale first principles matrix elements for S-O coupling for screening
|
| threshold_corr | 6.3 | # [eV] adjust Xray threshold energy
|
| core_hole_broad | 0.2 | # [eV] define core hole lifetime, Lorentzian
|
| final_state_broad | 0.12 | # [eV] final state lifetime, Lorentzian
|
| polar_in |
0.3420 0 0.9397 |
# define linear polarization direction of incoming Xray |
beam_out |
0.3420 0 0.9397 |
# outgoing Xray beam at right angle to incoming beam |
| spa |